1. Which of the following uses is permitted by the code
to be used for surface non-metallic
raceway?
A. Dry location
B. Where concealed
C. Where subject to physical damage
D. Where voltage is over 300v
ANS: A
2. Service entrance using copper conductors shall have
sufficient capacity and shall not be smaller than ________.
A. 5.5mm
B. 3.5mm
C. 14mm
D. 8.0mm
ANS: D
3. If two identical lamps give normal light when
connected in parallel in 230v line are reconnected in series in the same, the
bulb will ______________.
A. give more light
B. not light
C. give less light
D. blows out
ANS: C
4. When flexible metal conduit is installed as a fixed
raceway, it shall be secured within _______ on each side of every outlet box.
A. 250mm
B. 300mm
C. 100mm
D. 150mm
ANS: B
5. A short circuit can be detected by using_________ .
A. an ohmmeter
B. a meggar
C. an oscillscope
D. an ammeter
ANS: A
6. The electrical plants for residential house include
the following items EXCEPT one. Which one is this?
A. substation plan
B. location plan
C. floor plan showing location service
D. Layout of wiring paln for general lightning and
receptacles outlets
ANS: A
7. If installed in raceway, conductors of size _____ and
larger shall be stranded.
A. 5.5mm
B. 8.0mm
C. 14mm
D. 3.5mm
ANS: B
8. At least _______of free conductor shall be left each
outlet, junction and switch for splices or connection of fixtures o devices.
A. 250mm
B. 175mm
C. 150mm
D. 300mm
ANS: C
9. A certiain residential house has lightning load of
1.1 kVA and a appliance load of 10a at 220v single phase, two wires 60hz. The
branch circuit fuse protection for lightning anf appliances loads are ______
and_______, respective ly
A. 20A and 60A
B. 20 and 30
C. 15A and 30A
D. 15A and 20A
ANS: D
10. Live vegetation or trees _________ used for support
of overhead conductors spans.
A. shall be
B. should be
C. shall not be
D. should not be
ANS: C
11. Light fixtures suspended from the ceiling by chains
should wire so that the wires ______________ .
A. will be grounded
B. will not touch the chains
C. will support the fixture
D. will not support fixture
ANS: D
12. In rigid metal conduit wiring conduit of 15-20 mm
diameter shall be supported at least every _________.
A. 2 500mm
B. 3 500mm
C. 1 800mm
D. 3 000mm
ANS: D
13. Why do conductors need additional wiring insulators?
A. electrical wiring needs to be protected from
mechanical harm
B. wires are connected by joints therefore needs
reinsulations
C. wire touches wood surface therefore need protection
D. wires skin is weak
ANS: A
14. What is the total number of mechanical degrees that
electrical pipe run maybe bent between pull points?
A. 360 degrees
B. 180 degrees
C. 120 degrees
D. 270 degrees
ANS: A
15. Rigid non-metallic conduit shall be supported within
______ of each box cabinet or other termination.
A. 600mm
B. 800mm
C. 900mm
D. 760mm
ANS: C
16. Electrical metallic tubing smaller than ___
electrical trade size shall NOT be used.
A. 12mm
B. 10mm
C. 15mm
D. 20mm
ANS: C
17. Type AC cable shall be secured by approved staples,
straps, hanger or similar fitting at intervals NOT exceeding ________ .
A. 1 250mm
B. 1 300mm
C. 1 500mm
D. 1 000mm
ANS: B
18. In concealed knob and tubewiring the clearance to be
maintainde between conductors is _______ .
A. 65mm
B . 45mm
C. 76mm
D. 50mm
ANS: C
19. Three bulbs are connected in parallel and controlled
by a single switch. If one of the three 3 bulbs is busted, what will happen to
the remaining bulbs.
A. Will not lit
B. Its brightness is reduced
C. its brightness increases
D. its birghtness is maintiained.
ANS: D
20. Which is a synchronous alternating-current machine that
changes mechanical power into electrical power?
A. dynamo
B. Motor
C. Alternator
D. Lathe machine